Thống kê

313166
Số người đang online 3
Số truy cập hôm nay 58
Số truy cập tháng này 24753

Serie DÒ GAS DÂN DỤNG.

 

The Gas Seeker detector has been designed and built according to European regulations to detect, through the built-in catalytic sensor, the presence of Methane and LPG gas. The sensor is calibrated to detect a gas concentration at 10% of L. E. L. At the same time it ensures a high selectivity with regard to the interfering species usually present in household environments and that could often cause false

alarms (cooking, steams, wines, alcohol, cleaners, ammonia, etc. ).

A series of technical features make this detector extremely versatile, reliable, accurate, and safe.

The internal jumper makes it possible to select the relay impulse functioning to connect manual reset solenoid valves, or the continuous functioning to activate solenoid valves and/or sirens.

The relay, free of voltage, allows installation of multiple detectors on a single solenoid valve ensuring control of multiple dangerous environments.

Beyond the main alarm signal two pre-al arms were fitted. These are designed to advise the user earlier if compared to other standard detectors.

The device i s complete with a special circuit that controls the catalytic sensor’ s efficiency level, and signals any possible fault. The external container has an I P42 protection degree. These features make the Gas Seeker reliable for civil environment safety.

 

Technical Specifications

Power Supply: 230VAC 50/60 Hz +/- 1 0%

Current Consumption: 2VA

Range of relay contact switching: 10A 250V resistive

Gas sensor technology: Catalytic

Explosion Alarm Threshold: 10% L. E. L.

Faults detected: Interruption, short circuit, or wear

Signal alarm by: LED diode and buzzer

Test Phase Duration: 90 seconds

Functioning temperature: from -10°C to +40°C

Functioning Humidity: Lower than 90%

Body material: ABS

Dimensions: 170x108x39mm

External degree of protection: IP42

Electromagnetic Compatibility “CE”: EN 50270 Norms